COnventional Smoke Detector
video
COnventional Smoke Detector

COnventional Smoke Detector

Model: YJ-151L-2
Network Type: 2 Wire
Sensor: Photoelectronic
Power: Power supply non-polar input:DC 10~30V

YANJEN 2 or 4 Wire Network Conventional Smoke Detector

15155

This product is a photoelectric smoke detector works with network conventional fire alarm control panel. The product is divided into 2-wire detector and 4-wire detector according to its networking approach. The smoke chamber work under the principle of smoke particles. Reflecting infrared lights accurately detect early smoke of a fire. The smoke detector will go into alarm when signal level exceeds the alarm sensitivity and send the alarm signal to the fire alarm control panel, during an alarm, the LEDs will be constantly bright. The detectors are widely used in office buildings, shopping mall, banks, libraries and other indoor places.


Product Specifications:

Model

YJ-151L-2

Network Type

2 Wire

Sensor

Photoelectronic

Power

Power supply non-polar input:DC 10~30V

Current

Static Current :120uA, Alarm Current: 20mA@DC24V

Alarm Output

Remote LED Indicator

Working Environment

Operation Temperature-10℃~+55℃, Operation Humidity: <95%

Dimension

Φ100*60mm


Product Details:

MCU processing; Resist false alarm efficiently; Power-off reset; Remote LED indicator; Stainless steel shield; Anti-RFI interference; Sensitivity: 2.06%/ft; Detecting area:80㎡ @ 6-12m installation height; 60㎡ @ <6m installation height.

1511281

Application:

It has widely applicable places, like hotels, lounge, family house, etc.

1131558


Delivery:

Long-term cooperation forwarders, we can ship your goods safely and in time.

1131693

1. The detector cannot be installed under worse environment. E.g. cold, hot, dusty places. Do not move away the dust-proof cover until the detector was needed to use.

2. Make sure that there is no block within 0.5m from the detector.

3. Keep the distance between the detector and wall more than 0.5m.

4. Make sure the distance between detectors be less than 15m. The distance between detectors can corner must be less than half of the one between detectors.

5. Horizontally install the detector. If it has to be installed slantingly, please keep the angel less than 45 degrees.

6. Detector’s base must be installed solidly; wire connections must be reliable.

7. We suggest a simulated smoke tests every six months, the test is to make sure the detectors are working well.

8. For various reasons, including, but not limited to changes in environmental conditions, electric disruptions and tampering, the product may not perform as expected.The user is advised to take his / her safety and the protection of his / her property.